INPUT POWER
- Rated current: 94 amps ±15% @ 480 VAC, 60 Hz
OUTPUT
- 270 VDC @ 259 Adc - 72 kW
- 28 VDC @ 15 Adc - Interlock
- Voltage regulation: ±3 VDC
- Transient performance exceeds Mil-Std-704F
- Recovery from 95% Step Load in 40 ms to 704F requirements and
- 80 ms to recover to DC regulation
- Meets F-35 JSF power quality
requirements for Pulse Loads.
- Overload Rating:
- Limits total current between 460 – 490 Adc for 2s
- 125% for 6 seconds
- 150% for 3 seconds
EFFICIENCY
- 12 pulse Front End
- Overall efficiency:
>0,93 at 35-90 kVA load
>0,90 at 25 kVA load
- No load loss: <2 kW
PROTECTION
- No break power transfer
- Over/under voltage: Input and Output
|
- High temperature
- Internal system error
- Overload
- Short circuit
ENVIRONMENTAL
- Operating temperature: -40°C to +55°C
- Relative humidity 0—95%
- Airborne Noise <65 dba @ 1m - typically 60 dba
MISCELLANEOUS
- MTBF (Proven): 100,000 hours
- MTTR: max. 20 minutes
STANDARDS
- MIL-STD-704F Aircraft electric power characteristics
- Mil-STD-1399-300 Interface Standard for Shipboard Systems
- Mil-STD-1472F Human Engineering
- UFGS-26 35 43 Unified Guide Specification
- DFS 400 Specification for 400 Hz Aircraft Power
- BS 2G 219 General Reqment
- ETL Listed
EMI
MIL-STD-461E:
- CE102 Conducted Emissions, Power Leads, 10 kHz to 10 MHz
|
- CS101 Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz
- CS114 Conducted Susceptibility, Bulk Current Injection, 10 kHz to 200 MHz
- CS115 Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation
- CS116 Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz, 10A max for all configurations
- RE102 Radiated Emissions, Electrical Field, 10 kHz to 1 GHz
- RS103 Radiated Susceptibility, Electric Field, 2 MHz to 18 GHz
OPTIONS
- 270 VDC @ 30 Adc – 8.1 kW FTI
- External Emergency Stop
- Remote Control Box
- 6 pulse Front End
- 18” Floor Stand
- Trailer per SAE AS8090
- Auxiliary Power Outlets, 60 Hz
- Door/Panel Interlock
- Portable Service Lamp
- 415 VAC/50 Hz Input
|