INPUT POWER
- Rated current: 188 amps ±15% @ 480 VAC, 60 Hz
OUTPUT 270 VDC
- 270 VDC @ 259 Adc - 70 kW
- 28 VDC @ 15 Adc - Interlock
- Voltage regulation: ±3 VDC
- Transient performance exceeds MIL-STD-704F
- Recovery from 95% Step Load in 40 ms to 704F requirements and 80 ms to recover to DC regulation
- Meets F-35 JSF power quality requirements for Pulse Loads.
Overload Rating:
- Limits total current between 460 – 490 Adc for 2s
- 125% for 6 seconds
- 150% for 3 seconds
OUTPUT 400 Hz
- Power: 90 kVA @ 0.8 pf Lag
- 115/200 V – WYE, ABC-N
- Frequency: 400 Hz ± 0.1%
- Power factor: 0.5 lag to 0.9 lead
- Voltage regulation: <1%
- Transient performance exceeds MIL-STD-704F
|
- Crest factor: 1.414 ±3%
Overload Rating:
- 110% for 60 minutes
- 125% for 5 minutes
- 150% for 2 minutes
- 200% for 20 seconds
- 300% for 6 seconds
EFFICIENCY
- 12 pulse Front End
- Overall efficiency (270 VDC):
>0,93 at 35-90 kVA, 30%—100% load
>0,90 at 25 kVA, <30% load
- No load loss: <2 kW
PROTECTION
- Over/under voltage: Input and Output
- Overload
- Short circuit
- High temperature
- Internal system error
ENVIRONMENTAL
- Operating temperature: -40°C to +55°C
|
- Relative humidity 0—95%
- Airborne Noise <65 dba @ 1m - typically 60 dba
MISCELLANEOUS
- MTBF (Proven): 100,000 hours
- MTTR: max. 20 minutes
STANDARDS/SPECIFICATIONS
- UFGS-26 35 43 Unified Guide Specification
- MIL-STD-704F
- NFPA 70 Article 500
EMI HARDENED
- EMI Gasketing
- Screen Filter for Display
- EMI Input/Output Filters
- EMI Power Input/Output Filters
OPTIONS
- Remote Control Box
- 18” Floor Stand
|